v2026.11.16174
Guide / Troubleshooting

Troubleshooting

zCFD validates every deck before the solver starts, so a key that is misspelt, out of range or inconsistent with its neighbours is reported before the first cycle. Most of the symptoms below are ones validation cannot catch. Find the symptom in the table, confirm it with the check its section gives, then work through the causes in the order listed.

SymptomWhat the run showsSection
Residuals rise until the run stopsOne or more residual columns of the report file grow from cycle to cycleDiverging residuals
The run stops on a non-finite valueReport check at cycle ... in the logNaN or inf in the report
A compressible run fails and the cells that cause it are unknownhas an invalid solution lines in the log, and a <model>_fail outputLocating the failing cells
Residuals fall, then plateauA residual history that flattens well short of the targetConvergence stall
The inner-cycle residual flattens at the same level in every real time stepA floor in each real time step, while the integrated forces continue to settleLimiter switching
Divergence persists at a low CFL number and first order, or a stall is localA residual carried by a handful of cellsPoor mesh quality
The solver stops on a licence message, at start-up or during the runThe zCFD licence could not be initialised., No zCFD licence could be checked out for zcfd-core. or zCFD lost contact with the licence server for more than 10 minutes.Licence and launch failures
Validation rejects an output variableOutput variable error: Variables [...] are not valid for equation type ...Output variable rejected

Diverging residuals

The residuals in the <casename>_report.csv file should fall gradually as the solver converges, per real time step if the flow is unsteady. A run is diverging when one or more of them turns and rises instead. The divergence may follow a period of otherwise stable convergence, because a particular pattern in the flow can appear during the solution and destabilise the scheme. A diverging run that is left to continue ends on a non-finite value.

The typical form of a divergent set of residuals. Rather than decreasing, the values all start increasing significantly from cycle 45 onwards. In this case the NACA0012 case was deliberately set with an unstable explicit CFL number of 6.0.
The typical form of a divergent set of residuals. Rather than decreasing, the values all start increasing significantly from cycle 45 onwards. In this case the NACA0012 case was deliberately set with an unstable explicit CFL number of 6.0.

Confirm it. Plot the residual columns of the report file against the cycle, or watch them in zMon. For an implicit run using the AMGX library, the log also reports each solve of the implicit linear system: the number of iterations and the residual after each one. Typically 4 to 5 iterations are enough to achieve the desired reduction in residual, which is 3 to 4 orders of magnitude. If the number of iterations climbs above 6, the linear system may be poorly conditioned as a result of numerical instability in the solution.

Cycle 5003 (real time cycle: 0 time: 0)
CFL 20.0 (20.0) - MG 20.0 (coarse mesh: 0)
        iter      Mem Usage (GB)       residual           rate
        --------------------------------------------------------------
            Ini             36.9899   3.037596e-06
            0             36.9899   4.565379e-07         0.1503
            1             36.9899   1.138337e-07         0.2493
            2             36.9899   3.056741e-08         0.2685
            3             36.9899   1.061114e-08         0.3471
            4             36.9899   3.308933e-09         0.3118
            5             36.9899   1.293730e-09         0.3910
        --------------------------------------------------------------
        Total Iterations: 6
        Avg Convergence Rate: 	0.2743
        Final Residual: 		1.293730e-09
        Total Reduction in Residual:	4.259057e-04
        Maximum Memory Usage:	36.990 GB
        --------------------------------------------------------------
Total Time: 0.869665
    setup: 0.109454 s
    solve: 0.760211 s
    solve(per iteration): 0.126702 s
        iter      Mem Usage (GB)       residual           rate
        --------------------------------------------------------------
            Ini             36.9899   1.713350e-04
            0             36.9899   1.060694e-07	0.0006
            1             36.9899   1.898567e-10	0.0018
        --------------------------------------------------------------
        Total Iterations: 2
        Avg Convergence Rate:	0.0011
        Final Residual:		1.898567e-10
        Total Reduction in Residual:	1.108102e-06
        Maximum Memory Usage:	36.990 GB
        --------------------------------------------------------------

Example output from the AMGX implicit linear solver. In this case the turbulence equations are solved after the primary flow variables. The primary flow variables are solved in 5 cycles of the AMGX solver, achieving an order of magnitude 3 reduction in the residuals.

Work through the causes in this order. If the run still diverges once the first three have been tried, the cause is most likely the boundary conditions, preconditioning or the mesh quality.

CauseSettingFirst change
CFL number above the stability limit of the meshcflBelow 1.0, say 0.5, for an explicit run; 5.0 or less for an implicit run
Second-order spatial accuracyorderfirst
A less dissipative inviscid flux schemeinviscid_flux_schemerusanov
Wall function iterations that do not convergewall kindslip or no slip
An inconsistent set of boundary conditionsboundary_conditionsSimplify them, as described below
Preconditioning unsuited to the meshpreconditionFalse
Poor quality cellsPoor mesh qualityConfirm it, then remediate or improve the mesh

Numerical instability

The solver advances the flow solution towards convergence at the required level of spatial and temporal accuracy, subject to a user-defined limit called the CFL (Courant–Friedrichs–Lewy) number. The CFL number limits the update to the solution in each cycle to maintain the stability of the underlying numerical scheme.

There are formal criteria for the CFL number of a given scheme, but these typically apply only to idealised meshes: orthogonal or structured, with a very gradual variation in the volume ratio from cell to cell. For a complex mesh, or where cell quality is poor even in only a few cells, the limit for stability may be significantly lower. In explicit mode the theoretical CFL limit is approximately 1.0 for most schemes, though in many cases a higher value of 1.5 to 2.0 will work. In implicit mode the theoretical CFL limit is 1000 or more, and values between 10 and 100 are common.

Reducing the spatial order to first and the inviscid_flux_scheme to rusanov gives the most stable, though least accurate, discretisation.

Wall functions

zCFD scales a turbulent wall function on a solid boundary automatically. An internal iterative solution of a set of equations matches the flow speed and the wall shear stress in the cell adjacent to the wall to the ideal profile of a turbulent boundary layer. The number of internal iterations should be low, fewer than 20, if the solution is physically valid. zCFD reports the time per cycle in the AvgCycleTime column of the report file, and a value that starts climbing may indicate that the wall function iterations are not converging. To test whether the wall functions are the cause, change the wall kind from wall function to slip or no slip, whichever is the closer approximation to the desired behaviour.

Inconsistent boundary conditions

zCFD checks that each boundary condition in boundary_conditions is correctly specified, but it cannot determine whether a combination of boundary conditions is correct. A closed fluid domain with every boundary a solid wall except for a single mass flow condition, for example, will appear to converge at first, until the pressure rises or falls to non-physical levels. The effects of mismatched boundary conditions can also be more subtle, especially where inflow and outflow conditions over-specify or under-specify the solution.

To diagnose inconsistent boundary conditions, simplify them: replace wall functions with slip walls, and inflow and outflow conditions with farfield conditions of kind riemann. It can also help to repeat the simulation and stop the solver shortly before the crash, to inspect the solution for unexpected features. The temperature field often points to the areas of the flow that are causing problems, particularly where poor quality cells are present.

Preconditioning

The timestep of zCFD in explicit mode is limited by a local numerical wave speed in the solver scheme. In regions of low-speed flow, such as near stagnation points, this may be overly conservative. Preconditioning modifies the scheme to increase the local timestep, subject to a local stability condition. The stability limits of the preconditioned scheme may be inappropriate for a given mesh, however, and the flow field then diverges. To test this, set precondition in equations to False.

Parallel log files

For a parallel run, the main log file may not contain all of the information about a crash that the solution on one partition has caused. The log file for each partition is stored in the <case>_OUTPUT/LOGGING directory as <case>.<rank>.log.

NaN or inf in the report

The run stops with one of these messages, the first from a compressible run and the second from an incompressible one:

Report check at cycle <cycle>: the solution is invalid in <count> cells. It had already diverged, so these may not be the origin.
Report check at cycle <cycle>: the report is not finite.

A compressible run also names the invalid cells and writes them out; see Locating the failing cells.

Confirm it. The row holding the non-finite value is written to <casename>_report.csv before the run stops, so the last row of the file shows which column failed, and the rows above it show how the run arrived there. For a parallel run, read the log file of each partition as well as the main log.

What the rows before it showCause and remedy
Residuals that rose over the preceding rowsA divergence: see Diverging residuals
A residual carried by a handful of cells, or divergence at a low CFL numberSee Poor mesh quality

Locating the failing cells

When the solution of a compressible run becomes invalid, the run names the cells responsible, writes them out for inspection and stops. A cell is invalid when any of its conserved variables is NaN or inf, or when its density or pressure is not positive.

The log of the partition that owns an invalid cell carries one ERROR line for it. The line gives the global cell ID, the rank and the coordinates of the cell centre, then each conserved variable and the pressure, in SI units with the non-dimensional value alongside:

Cell <id> on rank <rank> at (<x>, <y>, <z>) has an invalid solution: <name>=<value> <unit> [nd <value>], ..., p=<value> Pa [nd <value>]

Each partition lists at most 20 cells and counts the remainder in a single line, <count> more invalid cells on rank <rank>. The main log then names the check that found the cells, the output it wrote and the last checkpoint written before the failure:

Report check at cycle <cycle>: the solution is invalid in <count> cells. It had already diverged, so these may not be the origin.
Wrote <case>_OUTPUT/<model>/<model>_fail.vtkhdf (volume + surface). Last good checkpoint: <path> at cycle <cycle>. Rerun from it with safe mode on.

If no checkpoint has been written, the line reads Last good checkpoint: none. Rerun with safe mode on. When safe mode is already on, the line ends at the checkpoint.

CheckWhen it runs
Start-up checkBefore the first cycle, on the solution the run starts from. A restart also logs the file and the turbulence model that wrote it
Safe-mode update checkAfter each explicit update on every multigrid level, when safe mode is on. On a coarse level the log names the level, and the cells listed are those of the fine mesh
Checkpoint checkEach time a checkpoint is due
Report checkWhen a row of the report file holds a non-finite value. The summary adds that the cells may not be where the divergence began

The failure output. The <model>_fail output is written to <case>_OUTPUT/<model>/: a volume file, <model>_fail.vtkhdf, and one surface file per boundary with the same prefix. It does not replace the checkpoint. Its variables are fixed and take the place of the lists in the deck:

  • volume: FailCell, GlobalCellId, var_1 to var_N and resvar_1 to resvar_N for the N conserved variables, pressure, temperature, mach, velocity, eddy, timestep, celllimiter, cellvolume, bad cells maximum non orthogonality angle, walldistance and cellzone;
  • surface: FailCell, pressure, temperature, cp, yplus and zone.

FailCell is 1 in an invalid cell and 0 elsewhere. On a surface, each face takes the value of the cell it belongs to.

Inspect it in ParaView. Open the volume file and apply a Threshold filter on FailCell with a lower bound of 1 to isolate the invalid cells. To find a cell named in the log, use Find Data on GlobalCellId with its global cell ID. Colour the surface files by FailCell to see which boundaries the invalid cells touch. The cell volume, the non-orthogonality angle and the wall distance in the same file help to judge whether the mesh is at fault, as described in Poor mesh quality.

Find the origin. With safe off, the update itself is not checked, and a non-finite value usually reaches the report first. By then the solution has already diverged over several updates, so the marked cells show where the divergence ended, which may not be where it began. Rerun from the last good checkpoint, setting restart to True in the initialisation block and safe to True in the solver settings block. Safe mode then checks every cell after each explicit update, and stops the run at the first update that leaves a cell invalid.

Safe mode synchronises every stage of the update, which slows the run considerably, so use it to diagnose a failing case and leave it off in production. It does not check implicit updates or the coarse multigrid levels. The incompressible solver does not name invalid cells.

Convergence stall

More common than divergence is convergence stall, in which the reported residuals fall at first and then plateau.

The convergence of the steady-state explicit solver has achieved an average residual reduction of 5 orders of magnitude and then stalled. The noise in the solution from 40k cycles onwards suggests that either the flow is not fundamentally steady-state or that multigrid is adding an error to the solution. The user must determine whether the level of convergence is sufficient for their purposes and if not whether to run an unsteady simulation or degrade the spatial accuracy.
The convergence of the steady-state explicit solver has achieved an average residual reduction of 5 orders of magnitude and then stalled. The noise in the solution from 40k cycles onwards suggests that either the flow is not fundamentally steady-state or that multigrid is adding an error to the solution. The user must determine whether the level of convergence is sufficient for their purposes and if not whether to run an unsteady simulation or degrade the spatial accuracy.

Confirm it. The residual history in the report file flattens and stays level. The residual statistics columns show whether the stall belongs to the whole field or to a handful of cells: a small Neff against a large mesh means a localised stall, which is a mesh quality question. The flow residuals may be stalled while the integrated properties of interest, such as lift, drag or mass flow, are converged well enough to be useful. That judgement rests with the engineer.

CauseSettingFirst change
An error introduced by multigridcycles in multigridTurn multigrid off after a set number of cycles
Physical unsteadiness in a steady-state simulationtype in time_settingsRun unsteady from the stalled solution, or degrade the accuracy
A physical time step too large for dual time steppingtime_stepReduce it
The limiter switching within the inner cyclesLimiter switchingFreeze the limiter

Multigrid

For explicit simulations, multigrid accelerates convergence by using a set of coarse meshes to propagate the longer-wavelength components of the solution through the domain faster than the CFL condition would allow on the finest mesh. In theory, and on idealised meshes, multigrid does not change the steady-state solution that is reached, or the pseudo-steady-state solution of an unsteady flow. On real meshes around complex geometry, however, multigrid introduces an error, and this can limit convergence. Setting cycles in the multigrid block turns multigrid off after that number of cycles, which removes the error.

Flow unsteadiness

A very common cause of convergence stall, particularly in steady-state simulations, is physical unsteadiness in the underlying flow. The solver is then attempting to find a steady-state solution to an unsteady problem, and the solution keeps changing from cycle to cycle. There are two approaches, depending on the flow features of interest.

If the unsteadiness matters, use the unconverged steady-state flow as the starting point for an unsteady simulation. If the stall is within the pseudo-steady cycles of an unsteady dual time-stepping solution, the physical time_step may be too large, and should be reduced.

If the unsteadiness is not of interest, the accuracy of the solution can be deliberately degraded to give a more 'average' steady-state flow. This might mean the rusanov inviscid flux scheme, first-order spatial accuracy, a coarser mesh, or a combination of these. The implicit mode of the solver can also filter the solution in time, since a higher CFL number allows larger time steps. This approach can cause solver instability and inaccuracy in the final solution, because the 'averaging' process is non-physical.

Limiter switching

Within the inner, pseudo-time cycles of an unsteady dual time-stepping simulation on the compressible solver, a common cause of apparent stall is the MUSCL limiter switching state from one iteration to the next in a small number of cells. Those cells keep producing a solution change that never decays. The reported residual is an RMS over all cells, so a handful of them is enough to hold the whole norm up at a floor, while the bulk of the field may be converging perfectly well behind it.

Confirm it. The residual drops cleanly for the first several inner cycles and then flattens at the same level in every real time step, while the integrated forces continue to settle. Judging this from the global residual is unreliable. Use the inner cycle convergence columns instead, which measure the drop within each real time step rather than an absolute level.

Adding inner cycles does not help, because the floor is not a problem of convergence rate.

CauseSettingFirst change
The limiter changing state in a few cellsfreeze_limiter_cycle in numerical_schemeSet it, to snapshot the limiter and hold it fixed thereafter
A solution that genuinely needs the limiter to keep adaptingtime_stepReduce it, so less has to change in each real time step
The outer-iteration floor of the incompressible coupled schemelinear solver, time_stepTighten the linear solver, or reduce the time step
The under-relaxation floor of the incompressible SIMPLE schemetarget_ordersSet the target from a run with the criterion off

The incompressible solver has no slope limiter and ignores freeze_limiter_cycle. An inner residual that flattens there is the outer iteration's own floor. Under the coupled scheme, tighten the linear solver or reduce the physical time step. Under SIMPLE, the floor is set by the under-relaxation, implicit_relax and pressure_relax in the scheme block, and it is reached within a handful of cycles. A target_orders above that floor can never be met, so set the target from a run with the criterion off rather than adding cycles.

Licence and launch failures

The solver stops at start-up with The zCFD licence could not be initialised. or No zCFD licence could be checked out for zcfd-core. A run that has already started may instead log Connection to license server failed retrying, and later stop with zCFD lost contact with the licence server for more than 10 minutes.

Confirm it. The lines printed before the stop name the failure. A failed start-up prints Error initializing license system or Error initializing license heart beat, followed by the licensing system's own description of the error. A failed checkout prints Error checking out license with the RLM status value, then the product, version and count requested, and the same description. Look the status value up in the licence error codes.

CauseWhere to look
No licence file in any of the locations searchedLicence: a .lic file in the directory the solver is started from, the lic directory of the installation, or RLM_LICENSE
A licence that has expired, or has not yet startedStatus value -3 or -37
More licences requested than are freeStatus value -8 or -22: reduce the number of ranks, or stop other running processes
No connection to the licence serverStatus value -17, -103 to -107 or -111 to -113: check the server, the firewall and RLM_LICENSE
A connection lost during the runThe heartbeat messages: see below

Once a run has started, a lost connection to the licence server does not stop it at once. The solver logs the retry warning and continues for up to 10 minutes. If the connection is not restored within that time, the run stops with zCFD lost contact with the licence server for more than 10 minutes.

Output variable rejected

Validation rejects the deck with a message of this form:

Output variable error: Variables ['kinematicviscosity'] are not valid for equation type 'viscous' in volume context. Valid variables include: [...]...

Confirm it. The message names the rejected variables, the equation type and whether the list is the surface or the volume one. Where a close spelling is valid, it adds Did you mean. The list it closes with shows only the first few valid names, so look the name up on the output variables page instead. Which names are valid, and why, is set out under Output variables.

Several names are rejected because the name an engineer reads in an output file, or would naturally write, is not the one a deck asks for:

Rejected nameRequest insteadWhy
kinematicviscositynunu is written to the output file as kinematicviscosity
turbulenceintensitytiti is written as turbulenceintensity
walldistancewalldistwalldist is written as walldistance
velocitygradientvelocitygradOnly the shorter spelling is valid
facecentrecentrecentre is the valid spelling in both contexts
frictionvelocityutOnly the short name is valid

A valid name can also be rejected because the case does not offer it:

CauseSetting
The name belongs to a higher tier than the equation type solvedtype in equations
A transition variable without the transition modelmodel in turbulence, set to sst-transition
A modal variable without FSIfsi on a wall boundary condition
A surface-only name in the volume list, or the reversesurface_variables, volume_variables
A var_i, resvar_i, resshare_i or vargrad_i index above the number of equations solvedtype and the turbulence model

A running average or RMS variable, such as p_avg or V_rms, passes validation whether or not averaging is on. If compute_average_and_rms is not set, the solver raises this error when it first writes the variable:

Averaged output variable requested but averaging storage is unallocated - set output_settings.compute_average_and_rms

Poor mesh quality

A run that still diverges once the CFL number, the spatial order and the inviscid flux scheme have been reduced, or a stall carried by a handful of cells, points to poor quality cells. The formal CFL criteria apply only to idealised meshes, and a few poor cells are enough to lower the limit for stability of the whole run.

Confirm it. A small Neff in the residual statistics columns, against a large mesh, means that the residual is carried by a few cells. Add the resshare_i volume output variables and threshold them at 1/Neff to find those cells. The temperature field often points to the same areas.

CauseSettingFirst change
Poor cells lowering the limit for stabilitycflReduce it
Poor cells that cannot be removed from the meshMesh quality remediationSet a threshold angle
A mesh that can be improvedPreparing a meshImprove the mesh, so the whole domain stays second order

Mesh quality remediation

{
  "solver_settings": {
    "type": "compressible",
    "mesh_quality_remediation_angle_threshold": 75
  }
}

A strongly non-orthogonal face can stop a second-order compressible solve from converging. The non-orthogonality of a face is the angle between the line joining the two cell centres on either side of it and the face normal. It is 0 degrees on an ideal mesh and grows as the cells skew.

Setting mesh_quality_remediation_angle_threshold computes the convective flux at first order on every interior face whose non-orthogonality exceeds the threshold, in degrees. Every other face keeps the order the numerical scheme sets. The key is unset by default, and no face is changed. When convergence problems are traced to mesh quality, 75 degrees is a reasonable first threshold. The first-order faces add numerical dissipation where they sit, so an improved mesh remains preferable to a remediated one for a final solution.

The setting applies to the compressible solver only. An incompressible deck that sets it fails validation.

At start-up the log reports the spread of face angles across the mesh and the number of faces changed:

[wing] mesh quality remediation: interior faces whose non-orthogonality exceeds 75 degrees use a first-order convective flux
 Mesh quality remediation: face non-orthogonality histogram
 Angle (deg) |  0 -> 20 | 20 -> 40 | 40 -> 60 | 60 -> 80 | 80 ->100 | 100->120 | 120->140 | 140->160 | 160->180 |
 Num faces   |    812345|     40211|      2310|       188|         4|         0|         0|         0|         0|
 Mesh quality remediation: face non-orthogonality ranges from 0 to 81.6 degrees
 Mesh quality remediation: 57 interior faces exceed the 75 degree threshold and use a first-order convective flux

Add badcells to volume_variables in the solution output to see where those faces lie. Each cell next to a first-order face holds the largest non-orthogonality among its first-order faces; every other cell holds 0.