Reference / Input deck / solver / output settings / report
report
Report and monitoring settings
frequencyrequiredvariablesmonitor›forces›mass flow›scale residuals by volumeresidual statisticsadvanced
frequencyrequired
int·required·>= 1
Report frequency (every N cycles)
variables
list of str·not set by default
Variables to include in reports
scale residuals by volume
bool·default False
Scale residuals by cell volume in reports
Used innaca0012
residual statisticsadvanced
bool·default True
Add the infinity norm of the true residual, its RMS, the participation ratio Neff and the worst cell's share of the total to the report, four columns per equation. Neff is the number of cells the residual is effectively spread over, so a small value against a large mesh means the field is converged everywhere except a handful of cells; the resshare_* output variables show which. On by default; set it False to save an extra pass over the residual field and two MPI reductions per report.