v2026.11.16174
Reference / Input deck / solver / output settings / solution

solution

Solution file output settings

format
default vtk

Output file format

Options
ValueWhat it doesWhen to use it
none

Outputs no files.

vtk default

Outputs in VTK HDF format (.vtkhdf) for reading into ParaView. The .vtkhdf output format requires ParaView 6.1.1 or later.

ensight

Writes the volume solution as EnSight files with VTK's EnSight writer, one set per output cycle. Surface output is still written as VTK HDF.

For post-processing in EnSight.

fwensight

Writes the same VTK HDF output as vtk, and in addition an EnSight Gold copy (.encas and .geo files) of the volume and of the boundaries.

native

Writes each volume variable to its own HDF5 file per output cycle, with an index file of external links to them. Surface output is still written as VTK HDF.

Guidance: Post-processing and visualisation →
surface variables
list of str·not set by default

Variables to output on surfaces

volume variables
list of str·not set by default

Variables to output in volume

scripts Catalyst Scriptsadvanced
list of str·not set by default

ParaView Catalyst Python scripts, run on the volume solution each time it is written. Paths are passed to Catalyst as written, so a relative path is taken from the directory the run is started in.

fwh interpolateadvanced
list of str·not set by default

List of stl files for FWH surface interpolation

Used incylinder
Guidance: Aeroacoustics (FWH) →
fwh wall dataadvanced
bool·default False

Record impermeable FWH data on every wall: the pressure and, for viscous equations, the wall shear stress. On a mesh that overset hole cutting can blank, each face is also flagged active or inactive, so a wall covered by another mesh does not radiate.

Used incylinder
Guidance: Aeroacoustics (FWH) →
write restartadvanced
bool·default True

Write restart files

Guidance: Choosing initialisation and reference state →
binaryadvanced
bool·default True

Use binary format

precisionadvanced
default single

Output precision

Options
ValueWhat it doesWhen to use it
single default

32-bit floating-point field values. The solver writes field data at this precision.

The default.

double

Accepted, but not read by the solver: field data is written in single precision whatever is set.

global node idsadvanced
bool·default True

Retain the local->global node map so VTKHDF output can stitch partitions together without a clean-to-grid filter

output solver cycleadvanced
bool·default False

Stamp VTKHDF output steps with the solver cycle number instead of physical time. Every step of a steady run carries the same physical time, so the default leaves the appended steps indistinguishable to a viewer; the cycle number makes them steppable

ghost cellsadvanced
bool·default True

Emit a one-cell-deep ghost layer in the VTKHDF volume output: the partition halo cells the solver already exchanges, marked DUPLICATECELL, so filters that interpolate cell data to points (isosurfaces, for instance) are correct across partition interfaces instead of showing a seam