Which solver runs the case, and how it is partitioned and parallelised

type
not set by default

The zCFD solver to be used

Options
ValueWhat it doesWhen to use it
compressible

The density-based solver for the compressible equations: euler, viscous, rans or les with an ideal gas.

Where density varies with pressure and temperature, including transonic and supersonic flow.

incompressible

The pressure-based solver for incompressible flow, coupling momentum and pressure with either the coupled or the simple scheme.

Low-speed flow in which density does not depend on pressure. Buoyancy and anelastic stratification are available through the energy equation.

solution smooth cyclesadvanced
int·default 0

Number of Laplace smoothing cycles for mapped solutions.

Guidance: Choosing initialisation and reference state →
safe
bool·default False

Enable safe mode for extra checks and diagnostics.

mesh quality remediation angle thresholdadvanced
float·not set by default·> 0 and <= 180·'mesh quality remediation angle threshold' only applies when solver.solver settings.type is 'compressible'

Non-orthogonality angle in degrees above which an interior face uses a first-order convective flux. Non-orthogonality is the angle between the line joining the two cell centres and the face normal. Unset leaves every face at the scheme's order.