New features

  • Added the run_fwh utility, which computes acoustic pressure histories at observer locations directly from a zCFD control file, including overset and rotating cases.
  • Simpler acoustic set-up, with dt and permeable now optional, automatic summation over surfaces, and utilities to view surface data by frequency in ParaView and to exclude chosen faces.
  • Time-averaged runs store averaged boundary data, which can be output and is kept across a restart.
  • The zmesh mesher can generate surrogate STLs for post-processing.

Changes in behaviour

  • Each initial condition block must give the velocity V as a vector.
  • A porous fluid zone can be defined by def alone; zone is optional.
  • Acoustic surface data from rotating meshes is written in the unrotated mesh frame.

Fixes